Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Rev. bras. oftalmol ; 83: e0004, 2024. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1535601

RESUMO

ABSTRACT This report was aimed at presenting a case of neurotrophic keratitis and concomitant SARS-CoV-2 infection in a patient who has recently undergone a corneal DALK transplant. One month after corneal transplantation with adequate corneal epithelialization, the patient presented neurotrophic keratitis with a torpid course of the corneal transplant coinciding with a SARS-CoV-2 infection, with an excessive host immune response. In addition, the patient presented a re-positivization of nasopharyngeal polymerase chain reaction of SARS-CoV-2 with past disease after starting treatment with autologous serum eye drops. The implications at the ophthalmological level of SARS-CoV-2 infection may be clarified as the time the illness progresses and we learn more about how it acts. In this case, the disparity of signs and symptoms, the antecedent of corneal surgery, and the possibility of a herpetic infection as a cause of the primary leukoma suggested neurotrophic keratitis. Nonetheless, the involvement of systemic SARS-CoV-2 infection in the process, triggering an excessive host immune response at the corneal level with an increase in inflammatory cytokines must be taken into account. No relationship was found between treatment with autologous serum and re-positivization of nasopharyngeal polymerase chain reaction, presenting the patient a favorable response to treatment.


RESUMO O objetivo deste relato foi apresentar um caso de ceratite neurotrófica e infecção concomitante por SARS-CoV-2 em paciente submetido recentemente a transplante de córnea DALK. Um mês após o transplante de córnea com adequada epitelização da córnea, o paciente apresentou ceratite neurotrófica com curso tórpido do transplante de córnea, coincidindo com infecção por SARS-CoV-2, com resposta imune excessiva do hospedeiro. Além disso, o paciente apresentou repositivização da reação em cadeia da polimerase nasofaríngeo de SARS-CoV-2, com doença pregressa após iniciar tratamento com colírio de soro autólogo. As implicações a nível oftalmológico da infecção por SARS-CoV-2, podem ser esclarecidas à medida que a doença progride e aprendemos mais sobre sua forma de atuação. Neste caso, a disparidade de sinais e sintomas, o antecedente de cirurgia de córnea e a possibilidade de infecção herpética como causa do leucoma primário sugeriram ceratite neurotrófica. No entanto, deve-se levar em consideração o envolvimento da infecção sistêmica por SARS-CoV-2 no processo, desencadeando uma resposta imune excessiva do hospedeiro no nível da córnea, com aumento de citocinas inflamatórias. Não foi encontrada relação entre o tratamento com soro autólogo e a repositivização da reação em cadeia da polimerase nasofaríngea, apresentando ao paciente uma resposta favorável ao tratamento.

2.
Arq. bras. oftalmol ; 87(3): e2022, 2024. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520215

RESUMO

ABSTRACT Purpose: To compare the 3-month results of treatment with 20% autologous serum or combination treatment with preservative-free artificial tears and 0.05% cyclosporine in patients with dry eye disease due to primary Sjögren's syndrome. Methods: A total of 130 eyes of 65 patients with newly diagnosed dry eye disease due to primary Sjögren's syndrome were included in the study. The patients were divided into two treatment groups: 66 eyes of 33 patients were assigned to the autologous serum treatment group, and 64 eyes of 32 patients were assigned to the combination treatment group. Schirmer test, tear break-up time and Ocular Surface Disease Index (OSDI) scores were recorded at pretreatment and at 3 months of treatment. Results: At 3 months of treatment, the mean Schirmer value and the mean tear break-up time were significantly higher in the combination treatment group (p<0.0001 and p=0.034, respectively). The OSDI score at 3 months was significantly lower in the autologous serum Group (p=0.004). When the two groups were evaluated separately, the improvements in Schirmer, tear break-up time test, and OSDI scores from before to after treatment were statistically significant: p<0.0001, p<0.001, and p<0.0001, respectively, for the authologus serum Group, and p<0.0001, p<0.001, and p<0.0001, respectively, for the combination treatment group. Conclusions: In short-term treatment of dry eye disease due to primary Sjögren's syndrome, treatment with autologous serum was significantly superior to -combination treatment with preservative-free artificial tears and 0.05% cyclosporine in terms of improvement in OSDI scores. Improvements in Schirmer test and tear break-up time scores were significantly superior in the group treated with preservative-free artificial tears and 0.05% cyclosporine.


RESUMO Objetivo: Comparar os resultados de 3 meses de soro autólogo a 20% com um tratamento combinado, ou seja, lubrificantes oculares sem conservantes e ciclosporina a 0,05% em pacientes com síndrome do olho seco devida à síndrome de Sjögren primária. Métodos: Foram incluídos no estudo 130 olhos de 65 pacientes recentemente diagnosticados com síndrome do olho seco devida à síndrome de Sjögren primária. Os pacientes foram divididos em dois grupos de tratamento, 66 olhos de 33 pacientes foram incluídos no grupo de tratamento com soro autólogo e 64 olhos de 32 pacientes foram incluídos no grupo de tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina. Os resultados do teste de Schirmer e do tempo de ruptura do filme lacrimal e os índices de doença da superfície ocular (OSDI) foram registrados antes e depois de três meses de tratamento. Resultados: Três meses após o tratamento, o valor médio do teste de Schirmer foi mais alto com significância estatística no grupo do tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina (p<0,0001) e o tempo de ruptura do filme lacrimal também foi significativamente maior nesse grupo (p=0,034). Também aos três meses, a doença da superfície ocular foi menor com significância estatística no grupo de tratamento com soro autólogo (p=0,004). Quando os dois grupos foram avaliados separadamente, a melhora no teste de Schirmer, o tempo de ruptura e a doença da superfície ocular antes e depois do tratamento tiveram diferenças estatisticamente significativas tanto no grupo de soro autólogo (p<0,0001, p<0,001 e p<0,0001, respectivamente) quanto no grupo de tratamento combinado (p<0,0001, p<0,001 e p<0,0001, respectivamente). Conclusões: No tratamento de curto prazo da síndrome do olho seco devida à síndrome de Sjögren primária, o tratamento com soro autólogo foi significativamente superior ao tratamento com lubrificantes oculares sem conservantes combinados com ciclosporina, em termos de melhora no doença da superfície ocular. As melhoras no teste de Schirmer e no tempo de ruptura do filme lacrimal foram significativamente maiores no grupo de tratamento combinado com lubrificantes oculares sem conservantes e ciclosporina.

3.
Rev. bras. oftalmol ; 80(1): 12-16, jan.-fev. 2021. tab, graf
Artigo em Português | LILACS | ID: biblio-1251322

RESUMO

RESUMO Objetivo: Avaliar o perfil clínico, epidemiológico e o impacto econômico do surto de conjuntivite no período 2017-2018 no município de Recife-PE. Métodos: Estudo transversal com base na análise de prontuários de pacientes com diagnóstico de conjuntivite, atendidos na emergência da Fundação Altino Ventura entre dezembro/2017 e março/2018. Os dados coletados incluíram manifestações oculares no exame, complicações subsequentes, manejo e dias de licença médica. Resultados: Dos 12.712 pacientes atendidos na FAV entre dezembro de 2017 e março de 2018, 6.359 (50,0%) foram diagnosticados com conjuntivite, dos quais 3.543 pacientes (55,7%) foram atendimentos únicos. A média de idade dos pacientes ao atendimento foi de 29,5 ± 14,1 anos (variação, 1-85 anos), com distribuição semelhante entre os sexos (2.288 casos [50,1%] masculino; 2.282 casos [49,9%] feminino). O diagnóstico mais comum foi conjuntivite sem pseudomembrana (5.645 casos [88,8%]). Hiperemia conjuntival (6.278 casos [98,7%]) e reação folicular (6.255 casos [98,4%]) foram os achados mais frequentes ao exame. A complicação mais frequente foi pseudomembrana (1.062 casos [16,7%]). Os colírios lubrificantes (4.308 [67,7%]) e os colírios de associação antibiótico com corticoide (2.033 [32%]) foram os mais prescritos no tratamento. A média de dias de atestado médico foi de 4,8 ± 2,9 dias (variação, 1- 47 dias) e a perda de produtividade estimada em R$1.159.329,14. Conclusão: O surto de conjuntivite em Pernambuco foi responsável por metade das consultas em um pronto-socorro oftalmológico. Surtos de conjuntivite podem causar um impacto econômico, uma vez que afeta principalmente adultos jovens em idade produtiva. As características clínicas observadas sugerem um surto de conjuntivite de etiologia viral.


Abstract Purpose: To evaluate the epidemiological and clinical profile and economic impact of the acute conjunctivitis outbreak in the period of 2017-2018 in Recife-PE. Methods: Cross-sectional study based on the analysis of medical records of patients diagnosed with conjunctivitis at the emergency room of the Altino Ventura Foundation (FAV) between December 2017 and March 2018. The collected data included ocular manifestations at examination, subsequent complications, management, and days of sick leave. Results: Out of 12,712 patients assisted at FAV from December 2017 to March 2018, 6,359 (50.0%) were diagnosed with conjunctivitis. The mean age of patients was 29.5 ± 14.1 years (range, 01-85 years), with similar distribution between sex (2,288 50.1% male; 2,282 49.9% female). The most common diagnosis was non-pseudomembranous conjunctivitis (5,645 cases 88.8%). Conjunctival hyperemia (6,278 cases 98.7%) and follicular reaction (6,255 cases 98.4%) were the most frequent ocular findings. The most common complication was pseudomembrane in 1,062 cases (16.7%). Lubricants (4,308 67.7%) and antibiotic associated to corticosteroid eyedrops (2,033 32.0%) were the most prescribed medications. The average days of sick leave per patient was 4.8 ± 2.9 days (range, 1- 47 days) and the productivity loss estimated in R$1.159.329,14. Conclusion: The conjunctivitis outbreak in Pernambuco, Brazil was responsible for half of the consultations in an ophthalmic emergency room. Conjunctivitis outbreaks may cause an economic impact as it mostly affects young adults in their productive ages and take in average a 5-day sick leave. The clinical characteristics observed suggest an outbreak of conjunctivitis of viral etiology.


Assuntos
Humanos , Masculino , Feminino , Lactente , Pré-Escolar , Criança , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Soluções Oftálmicas/uso terapêutico , Licença Médica/economia , Conjuntivite/diagnóstico , Conjuntivite/tratamento farmacológico , Conjuntivite/epidemiologia , Lubrificantes Oftálmicos/uso terapêutico , Brasil , Estudos Transversais
4.
Arq. bras. oftalmol ; 82(5): 436-445, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1019427

RESUMO

ABSTRACT This systematic review aimed to assess the effectiveness of using preservative-free artificial tears versus preserved lubricants for the treatment of dry eyes in Universidade Federal de Alagoas (PROSPERO 2018 CRD42018089933). Online databases were searched (LILACS, EMBASE, MEDLINE, and CENTRAL) from inception to April 2018; references from included papers were also searched. The following keywords were used: lubricants OR artificial tears OR artificial tears, lubricants AND dry eye OR dry eye syndrome OR syndromes, dry eye OR dry eyes. Among the 2028 electronic search results, 29 full papers were retrieved and four were considered relevant. The number of participants from these studies ranged from 15 to 76. Meta-analysis was possible for the following outcomes: score of symptoms according to the Ocular Surface Disease Index - Allergan (OSDI), tear secretion rate using the Schirmer test, tear evaporation rate using the tear film breakup time test, burning, foreign body sensation, and photophobia. No statistically significant difference was observed between the two groups, and no side effects were attributed to the interventions. Evidence proving that preservative-free artificial tears are more effective than preserved artificial tears is lacking.


RESUMO Esta revisão sistemática teve como objetivo avaliar a eficácia do uso de lágrimas artificiais sem conservantes em comparação com lubrificantes preservados no tratamento do olho seco na Universidade Federal de Alagoas (PROSPERO 2018 CRD42018089933). As bases de dados online foram pesquisadas (LILACS, EMBASE, MEDLINE e CENTRAL) desde o início até abril de 2018; referências de artigos incluídos também foram pesquisadas. Foram utilizados os seguintes descritores: lubrificantes OU lágrimas artificiais OU lágrimas artificiais, lubrificantes E olho seco OU síndrome do olho seco OU síndromes, olho seco OU olhos secos. Dos 2028 resultados de busca eletrônica, 29 artigos completos foram recuperados, e quatro foram considerados relevantes. O número de participantes desses estudos variou de 15 e 76. A meta-análise foi possível para as seguintes variáveis: escore de desfecho dos sintomas de acordo com o Índice de Doença da Superfície Ocular - Allergan (OSDI), taxa de secreção lacrimal pelo teste de Schirmer, taxa de evaporação lacrimal usando o teste de tempo de ruptura do filme lacrimal, queimação, sensação de corpo estranho e fotofobia. Nenhuma diferença estatisticamente significativa foi observada entre os dois grupos, e nenhum efeito adverso foi atribuído às intervenções. Evidências provando que as lágrimas artificiais sem conservantes são mais eficazes do que as lágrimas artificiais preservadas estão faltando.


Assuntos
Humanos , Masculino , Feminino , Soluções Oftálmicas/farmacologia , Conservantes Farmacêuticos/farmacologia , Síndromes do Olho Seco/tratamento farmacológico , Lubrificantes Oftálmicos/farmacologia , Soluções Oftálmicas/uso terapêutico , Conservantes Farmacêuticos/uso terapêutico , Lágrimas , Viés , Lubrificantes Oftálmicos/uso terapêutico
5.
Full dent. sci ; 9(34): 92-99, 2018. ilus, tab, graf
Artigo em Português | BBO - Odontologia | ID: biblio-988236

RESUMO

A restauração de dentes por sistemas adesivos é rotina em odontologia. O tratamento do esmalte inicia-se pela profilaxia e asperização dos prismas. A manobra é feita com brocas adaptadas à canetas de alta ou baixa rotação as quais devem ser lubrificadas frequentemente. Diversos fatores podem provocar falhas nas restaurações, entre eles a contaminação por oleosidade. A proposta do trabalho foi verificar a influência da lubrificação das pontas de alta rotação na adesão de resinas compostas ao esmalte. Foram confeccionados 30 corpos de provas, constituídos de cilindros de PVC, nos quais se incluiu fragmento da superfície vestibular de dente bovino em resina acrílica autopolimerizável, de maneira paralela ao solo, com área suficiente para a colagem de braquete de 9 mm2. A amostra foi dividida em três grupos de 10. No primeiro (A), cada braquete foi colado de maneira convencional com uma asperização prévia do esmalte realizada com caneta sem lubrificação. No segundo (B), foi realizada asperização com caneta lubrificada e pré-acionada por 30 segundos. E no terceiro (C), a asperização foi feita imediatamente após a lubrificação. Cada braquete foi submetido ao teste de tração. Todas as falhas foram coesivas, apresentando valores médios de 73,18N para o grupo A, 75,90N para o B e 91,45N para o C. O tratamento estatístico não mostrou diferença significativa entre os grupos. De acordo com o método instituído não houve influência da lubrificação das pontas de alta rotação na adesão de resinas compostas ao esmalte (AU).


The use of adhesive systems is a routine procedure in restorative dentistry. Enamel treatment starts with prophylaxis and abrasion of enamel prisms. This is performed using drills adapted to high or slow speed handpieces which must be frequently lubricated. Many factors may produce failure in tooth restoration, among them is the contamination by oil. The purpose of this study was to assess the influence of high speed handpiece lubrication in bond strength of composite resin to enamel. Thirty specimen were made constituted of PVC cylinders, in which were included fragments of the vestibular surface of the bovine tooth in self-polymerized acrylic resin parallel to the floor with sufficient area for bonding the 9 mm2 bracket. The samples were divided randomly into three groups of 10. In the first group (A), the bracket was bonded using the conventional way and enamel abrasion was previously performed with an unlubricated handpiece. In the second one (B), abrasion was performed with a lubricated handpiece which was run on air for 30 seconds and in the third group (C), abrasion was made immediately after lubrication. A tensile test was carried out for each bracket. All failures were cohesive with mean values of 73,18N (group A), 75,90N (group B) and 91,45N (group C). Statistical tests detected no significant differences between the groups. According to the established method, there was no influence of high speed handpiece lubrication on bond strength of composite resin to enamel (AU).


Assuntos
Animais , Bovinos , Adesividade , Resinas Compostas , Esmalte Dentário , Lubrificantes , Análise de Variância
6.
Rev. bras. oftalmol ; 76(1): 23-27, Jan.-Feb. 2017. tab, graf
Artigo em Português | LILACS | ID: biblio-844060

RESUMO

RESUMO Objetivo: Avaliar a variação intra e interexaminadores do volume de gotas dispensados de frascos de colírios lubrificantes disponíveis no mercado. Métodos: Foram estudados cinco frascos de colírios lubrificantes e dezenove voluntários participaram deste estudo. A massa média de gotas de 20µl dos colírios foi obtida utilizando micropipeta e balança de precisão e como padrão para comparação com a massa das gotas obtidas pelos voluntários. Cinco gotas de cada frasco foram pesadas individualmente com o tubo de colírio perpendicular à balança, usando o primeiro e segundo dedos da mão direita, de forma que a pressão fosse aplicada somente no meio do frasco. Os experimentos foram realizados em uma sala climatizada a temperatura ambiente (21±1°C). Resultados: Todos os frascos de colírios apresentaram variação estatisticamente significante das massas das gotas obtidas pelos examinadores quando comparadas com a massa média padrão de 0,0182±0,0014g, com exceção da comparação entre os dados do colírio A com o colírio D, que não apresentou variação estatisticamente significante. Conclusão: O presente estudo demonstra a ausência de uniformidade das gotas dispensadas pelos frascos de colírios disponíveis no mercado e a sua inadequação à real necessidade, uma vez que as gotas dispensadas são maiores do que o indicado. Esse fato torna-se um problema quando se trata de período de tratamento prolongado, especialmente com colírios dispendiosos como os indicados para a terapêutica do glaucoma. Nesse sentido, a padronização das gotas de colírios se faz necessária.


ABSTRACT Objective: To evaluate the intra and inter variations of eye drops volume dispensed from bottles available on the market. Methods: Five bottles of lubricant eye drops were studied and nineteen volunteers participated in this study. The average mass from 20µl of eye drops was obtained using accuracy micropipette and balance, and used as standard for comparison with the mass of the drops obtained by the volunteers. Five drops of each vial were individually weighed with the tube perpendicular to the balance, using the first and second fingers of the right hand, so that the pressure was applied only in the middle of the flask. The experiments were performed in a room temperature (21±1°C). Results: All eye drops bottles showed a statistically significant variation on masses of the drops obtained by examiners when compared with the standard average weight of 0.0182±0,0014g, except when compared A with D eye drops, with no statistically significant variation. Conclusion: This study demonstrates the lack of uniformity of drops dispensed by eye drops bottles available in the market and its inadequacy to the real need, since the dispensed drops are larger than indicated.This fact becomes a problem when it comes to long treatment period, especially with expensive drops as indicated for glaucoma therapy. In this sense, the standardization of drops of eye drops is necessary.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Embalagem de Medicamentos/normas , Lubrificantes Oftálmicos/administração & dosagem , Lubrificantes Oftálmicos/normas , Instilação de Medicamentos , Esquema de Medicação , Custos de Medicamentos , Desenho de Equipamento , Lubrificantes Oftálmicos/economia
7.
Rev. bras. oftalmol ; 75(6): 447-451, nov.-dez. 2016. tab, ilus
Artigo em Português | LILACS | ID: biblio-829977

RESUMO

RESUMO Objetivo: Determinar o grau de dificuldade para instilação tópica ocular em idosos, com ou sem o auxílio de dispositivo de apoio facial, por meio de questionário. Observar qual método foi tecnicamente melhor para aplicação tópica ocular de gotas. Métodos: O estudo foi um ensaio clínico, controlado, randomizado e pareado, realizado em 50 pacientes idosos de setembro de 2015 a junho de 2016 na Policlínica Ronaldo Gazolla, Lapa-Rio de Janeiro. Um frasco de colírio Optive® foi acoplado ao dispositivo de apoio facial denominado Eyedrop®. Cada participante instilou o colírio com ou sem o auxílio do dispositivo em cada um dos olhos, sendo que a seleção ocular foi feita aleatoriamente. Foi perguntado ao paciente questões pré-formuladas sobre a dificuldade de ambos os métodos e a técnica de administração tópica ocular foi avaliada. Resultados: A instilação de gotas foi considerada difícil ou muito difícil por 10% dos idosos com o auxílio do dispositivo e por 36% sem o auxílio (p = 0,0047). Houve toque da ponta do colírio com os tecidos oculares em 64% dos pacientes que não usaram o Eyedrop® e em 4% dos que o utilizaram (p=0,000001). A maior dificuldade descrita na instilação tradicional foi acertar o olho com a gota (32%) e com o dispositivo de apoio foi entender seu uso(4%). Conclusão: A maioria dos idosos instila colírios erroneamente, tocando a ponta do frasco em tecidos oculares, o que favorece sua contaminação. O dispositivo de apoio facial tornou mais segura e fácil a instilação.


ABSTRACT Objective: To determine the degree of difficulty for topical ocular instillation in the elderly, through a questionnaire, with or without the aid of facial support device. Observe which method was technically better to topical ocular application of drops. Methods: The study was a clinical trial, controlled, randomized and paired, which was conducted in 50 elderly patients from September 2015 to June 2016 at the Polyclinic Ronaldo Gazolla, Lapa, Rio de Janeiro. A Optive® eyedrop bottle was attached to a facial support device called Eyedrop®. Each participant instilled an eye drop with or without the device help in each of both eyes, wherein the eye selection was made randomly. He was asked to answer pre-formulated questions about the difficulty of both methods and the topical ocular administration technique was evaluated. Results: Eye drop instillation was difficult or very difficult for 10% of the elderly with the device aid and for 36% without it (p = 0.0047). There were bottle tip touch onto the ocular tissues in 64% of patients who did not use Eyedrop® and 4% who used it (p = 0.000001). The greatest difficulty described in traditional instillation was to head properly the eye drop (32%) and when the support device was used, it was to understand how to use it (4%). Conclusion: Most elderly instills eye drops mistakenly, touching the tip of the bottle onto ocular tissues, which favors contamination. The facial support device increased security and facility in instillation.


Assuntos
Humanos , Masculino , Feminino , Idoso , Administração Tópica , Equipamentos e Provisões , Olho/efeitos dos fármacos , Lubrificantes Oftálmicos , Soluções Oftálmicas/administração & dosagem , Percepção , Ensaio Clínico Controlado Aleatório , Inquéritos e Questionários
8.
Ciênc. rural ; 46(11): 2055-2063, Nov. 2016. tab
Artigo em Inglês | LILACS | ID: lil-796067

RESUMO

ABSTRACT: Ocular lubricants are used to supplement one or more layers of the lacrimal film. They are often prescribed to treat keratoconjunctivitis sicca (KCS) and other diseases of ocular surface in humans. These lubricants may also protect the ocular surface and promote epithelial regeneration. The active component of ocular lubricants is the lubricating agent. The key properties of different lubricating agents are the electrolyte composition, osmolarity, and addition of preservatives. Although lacrimomimetics are not typically used to treat KCS in dogs, they can be used as an adjunctive therapy. Knowledge of the properties of lacrimomimetics will help in making the appropriate therapeutic choice.


RESUMO: Lubrificantes oculares são usados como suplementos de uma ou mais camadas do filme lacrimal. São frequentemente prescritos para o tratamento da ceratoconjuntivite seca (CCS) no homem e em outras afecções da superfície ocular. Seu uso também pode gerar proteção da superfície ocular e promover regeneração epitelial. Os principais componentes de sua formulação são os agentes lubrificantes e as principais propriedades são a composição eletrolítica, a osmolaridade e a presença de conservantes. Embora lacrimomiméticos não sejam o tratamento da CCS em cães, eles podem ser utilizados como terapia adjuvante. O conhecimento de suas propriedades auxiliará na melhor opção terapêutica.

9.
Eng. sanit. ambient ; 21(3): 561-568, jul.-set. 2016. tab, graf
Artigo em Português | LILACS | ID: lil-794654

RESUMO

RESUMO: Este trabalho aborda a questão do gerenciamento de embalagens pós-consumo de lubrificantes automotivos, considerando as dificuldades inerentes à implementação do sistema de logística reversa - prática compulsória por força de lei (Brasil, Lei 12.305/2010) - e a ineficácia dos atuais métodos utilizados para remoção da fração oleosa residual, necessária ao reprocessamento do material plástico por reciclagem mecânica direta. Para determinar metodologia apropriada para limpeza dos frascos de lubrificantes foram conduzidos experimentos para avaliar a influência do aquecimento e da posição das embalagens durante o processo de drenagem gravitacional. O procedimento analítico realizado proporcionou a escolha de uma combinação de variáveis capaz de assegurar remoção de elevado teor do resíduo oleoso com menor gasto energético. A otimização foi feita utilizando um planejamento experimental do tipo composto central com triplicata no ponto central. Os dados obtidos nos ensaios foram analisados com recursos estatísticos e demonstraram que ambos os parâmetros avaliados interferem, de forma significativa, no processo em estudo. Os resultados apontaram aumento da eficácia do processo quando a drenagem é realizada em temperaturas superiores a 35ºC e com a embalagem inclinada em ângulos próximos a 70º em relação à horizontal. Nessas condições, percentuais de remoção de óleo residual superaram 95% após 35 minutos de drenagem.


ABSTRACT: This work addresses the management of automotive lubricants packages after lubricant use, considering the difficulties of implementing reverse logistics system - compulsory practice by virtue of Law (Brazil, Law 12,305/2010) - and the poor effectiveness of the current methods for removing residual oil from packages, which is required before reprocessing plastic material in direct mechanical recycling. Experiments were conducted in order to determine the appropriate methodology for cleaning the lubricant bottles, evaluating the influence of temperature and package position in the gravitational drainage. This analytical procedure elicited a combination of variables and conditions capable of improving the removal of oily residue with less energy. The experimental optimization was performed using a central composite model with triplicate center point. The test results were statistically analyzed and showed that both parameters have significant influence on the separation process. The data indicated that the process is more effective when the drainage is performed above 35ºC and the packaging inclined at angles close to 70º relative to horizontal. Under these conditions, the oil removal is greater than 95% after 35 minutes of drainage.

10.
Rev. bras. oftalmol ; 74(6): 339-344, nov.-dez. 2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-767076

RESUMO

RESUMO Objetivo: Determinar o volume médio das gotas produzidas pelos colírios lubrificantes em diferentes ângulos de inclinação e determinar o custo médio do tratamento. Métodos: Determinação do volume da gota de 3 frascos originais dos colírios lubrificantes Artelac®, Hylo Comod®, Lacrima® Plus, Systane® UL, Lacrifilm®, Hyabak®, Lacribell®, Ecofilm®, Mirugell®, Plenigell®, Fresh Tears®, Optive® e Endura® à inclinação de 90º e 45º. Determinou-se o número médio de gotas em cada frasco e foi feita avaliação farmacoeconômica dos colírios. Resultados: O volume das gotas variou de 32,2 a 64,0 µL a 45o e de 29,1 a 65,1 µL a 90o. A diferença entre as gotas em cada inclinação foi de 2 a 24% e o custo anual dos colírios de acordo com a inclinação variou de R$2,73 a R$130,73. A Duração Máxima de Tratamento (DMT) foi de 29,3 a 51,4 dias na inclinação de 45o, e de 28,8 a 48,4 dias a 90º, sendo que a diferença na DMT foi de 0,5 até 8 dias a mais ou a menos, de acordo com a marca. Conclusão: Nenhum dos colírios estudados apresentou gotas ideais para o olho humano, levando a um desperdício do produto e maior custo para o fabricante e para o consumidor. Percebemos que existe uma variação significativa no volume da gota de acordo com a inclinação do frasco, e que uma variação maior do que 10% traria impactos financeiros para o paciente.


ABSTRACT Objective: To determine the mean drop volume produced by artificial tear solutions in different inclination angles and to determine the mean cost of the treatment. Methods: The drop volume of 3 original bottles of the artificial tear solutions Artelac®, Hylo Comod®, Lacrima® Plus, Systane® UL, Lacrifilm®, Hyabak®, Lacribell®, Ecofilm®, Mirugell®, Plenigell®, Fresh Tears®, Optive® and Endura® were determined at the inclination of 90º and 45º. The mean number of drops in each bottle was determined and a pharmacoeconomic evaluation of the drops was made. Results: The drop volume ranged from 32.2 to 64.0 µL at 45º and from 29.1 to 65.1 µL at 90º. The difference between drops in each inclination varied from 2 to 24%. The annual cost was from R$2,73 to R$130,73 according to the inclination of the bottle. The Maximum Duration of Treatment (MDT) was from 29.3 to 51.4 days at 45o and from 28.8 to 48.4 days at 90º, being the difference in MDT from 0.5 to 8 more or less days depending on each brand. Conclusion: None of the collyria studied presented ideal drops for human eyes, leading to a waste of the product and higher cost for the manufacturer and the consumer. We noted that there is a significant variation in the drop volume according to the inclination of the bottle, and that a variation of over 10% would bring financial impact for the patient.


Assuntos
Farmacoeconomia , Densitometria/métodos , Lubrificantes Oftálmicos/administração & dosagem , Lubrificantes Oftálmicos/economia , Lubrificantes Oftálmicos/normas , Instilação de Medicamentos , Custos de Medicamentos , Embalagem de Medicamentos/economia , Embalagem de Medicamentos/normas
11.
Rev. bras. oftalmol ; 74(1): 20-23, Jan-Feb/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-741926

RESUMO

Objective: To identify microscopic morphological alterations in the surface of silicone tubes used for intubation of the lachrymal system after exposure to ophthalmological lubricants. Methods: Experimental, descriptive and longitudinal study consisted of the application of ophthalmological lubricants in silicone tubes. The tubes were divided in: Group 1 (Cylocort®), 2 (Epitezan®), 3 (Labcaína®), 4 (Liposic®), 5 (Maxinom®) and 6 (Vista Gel®). One tube was not exposed to any lubricant, used as control. The tubes were observed and photographed after 2 hours, 30 days, 45 days before and after cleaning the surface and lumen. The following aspects were observed: surface (regularity, transparency, quantity, size and shape of the substances) and lumen (obstruction). Results: Control: irregular surface with pores after 2 hours: Group 1 – irregular surface with presence of film; Groups 2, 3 and 5 – abundant and irregular quantity of ointment at the surface; Group 4 – discrete modification at the surface; Group 6 – growth of pigmented (brownish) structures with filaments in the lumen, with discrete film in the surface. 30 Days: Groups 1, 4 and 5 – increase of the irregular superficial film; Group 2 – crust with notorious horizontal lines; Group 3 – diminution of the superficial film; Group 4 – crust less evident. Group 6 – increase of the structure seen with 2 hours of exposition, arboriform aspect. Forty-five days pre cleaning: Group 4 – diminution of the surface crust; Group 6 – expansion of the arboriform structure; unaltered findings in other groups. 45 days after cleaning: Groups 1 and 5 – light diminution of the surface crust; Groups 2, 3 and 4 – kept the modifications; Group 6 – the structure inside the lumen was not identified, clear surface, without evidence of film. Conclusions: Microscopic morphological alterations in the surface and lumen of silicone...


Objetivo: Identificar alterações morfológicas na superfície de tubos de silicone usados para intubação do sistema lacrimal após exposição a lubrificantes oftalmológicos. Métodos: Estudo experimental, descritivo e longitudinal que consistiu na aplicação de lubrificantes oftalmológicos em tubos de silicone. Os tubos foram divididos em: Grupo 1 (Cylocort®), 2 (Epitezan®), 3 (Labcaína®), 4 (Liposic®), 5 (Maxinom®) e 6 (Vista Gel®). Um tubo não foi exposto a nenhum lubrificante, sendo usado como controle. Os tubos foram observados e fotografados após 2 horas, 30 dias, 45 dias antes e após limpeza da sua superfície e lúmen. Os seguintes aspectos foram observados: superfície (regularidade, transparência, quantidade, tamanho e formato das substâncias) e lúmen (obstrução). Resultados: Controle – superfície irregular com poros. Após 2 horas: Grupo 1 – superfície irregular com presença de filme; Grupos 2,3 e 5 – quantidade abundante e irregular de pomada na superfície; Grupo 4 – discreta modificação da superfície; Grupo 6 – crescimento de estrutura pigmentada (marrom) com filamentos no lúmen, com discreto filme na superfície. Trinta dias: Grupos 1, 4 e 5 – aumento do filme irregular na superfície; Grupo 2 – crosta com linhas horizontais; Grupo 3 – diminuição do filme superficial; Grupo 4 – crosta menos evidente; Grupo 6 – aumento da estrutura vista com 2 horas de exposição, aspect arboriforme. Quarenta e cinco pré-limpeza: Grupo 4 – diminuição da crosta superficial; Grupo 6 – aumento da estrutura arboriforme; os demais grupos sem alterações. Quarenta e cinco dias pós-limpeza: Grupo 1 e 5 – discreta diminuição da crosta superficial; Grupos 2, 3 e 4 – modificações mantidas; Grupo 6 – a estrutura dentro do lúmen não foi visualizada, superfície limpa sem evidência de filme. Conclusão: As modificações na morfologia microscópica na superfície e lúmen de tubos de...


Assuntos
Intubação , Aparelho Lacrimal , Lubrificantes Oftálmicos , Tubulações , Silicones , Epidemiologia Descritiva , Ensaio Clínico , Estudos Longitudinais
12.
RBM rev. bras. med ; 71(8)ago. 2014.
Artigo em Português | LILACS | ID: lil-725912

RESUMO

Introdução: O uso de lubrificantes íntimos pode ser recomendado para reduzir o desconforto da lubrificação insuficiente, proporcionando conforto aos parceiros, particularmente em mulheres portadoras de ressecamento vaginal, decorrente da menopausa ou por outras condições ginecológicas1. Os lubrificantes íntimos são compostos por géis inertes ou que contenham ingredientes com ação calmante1. O presente estudo avaliou a segurança e a tolerabilidade de um gel lubrificante íntimo. Métodos: 115 voluntárias foram avaliados nas etapas do estudo. Inicialmente 55 voluntárias participaram de uma etapa para avaliação de potencial irritante primário e cumulativo e sensibilizante, através de aplicações repetidas de apósitos oclusivos no dorso. Paralelamente 27 voluntárias participaram de uma etapa para avaliação de potencial fotoirritante e fotossensibilizante através de aplicações repetidas de apósitos oclusivos, combinadas com irradiação com UVA. Finalmente, 35 voluntárias com queixas de dispareunia e ressecamento vaginal participaram de um estudo sob condições normais de uso, com utilização do produto durante 21 dias. As voluntárias responderam a um questionário sobre a performance do produto. Resultados: Não foi observada nenhuma positividade nos estudos de dermatotoxicologia. No estudo de segurança e tolerabilidade, nenhum evento adverso foi observado. O produto foi bem avaliado pela maior parte dos voluntários, que referiram maior lubrificação e sensação de bem-estar durante o ato sexual. Conclusão: O lubrificante íntimo avaliado no presente estudo demonstrou ser seguro e foi capaz de promover uma melhora da lubrificação íntima, promovendo uma melhor qualidade do ato sexual. O produto pode ser declarado como hipoalergênico, pela ausência de positividade nos estudos de dermatotoxicologia...


Assuntos
Humanos , Feminino , Adulto Jovem , Coito , Genitália Feminina , Lubrificantes
13.
Rev. bras. oftalmol ; 73(2): 98-102, Mar-Apr/2014. graf
Artigo em Português | LILACS | ID: lil-718431

RESUMO

Objetivo: Avaliar por questionário qual o nível de facilidade ou dificuldade para aplicação tópica de medicações oculares: vaporização em olho fechado ou instilação de gotas em olho aberto e constatar por meio da observação de pacientes pelos autores qual o método que foi utilizado com maior adequação técnica para aplicação de drogas tópicas oculares. Métodos: A pesquisa foi um ensaio clínico pareado e randomizado, realizada nos meses de agosto e setembro de 2012 no ambulatório de Oftalmologia da Policlínica Ronaldo Gazolla (Campus Arcos da Lapa, Faculdade de Medicina da Universidade Estácio de Sá, RJ) em 50 pacientes conveniados de planos de saúde ou do SUS. Foi utilizado um frasco de colírio e um de vaporizador com solução Optive®. Cada participante aplicou em um dos olhos a solução por vaporização ou instilação de gotas através de um processo randomizado. Foi perguntado aos pacientes questões pré-formuladas sobre a praticidade de ambos os métodos e observada à técnica de aplicação. Resultados: 32% acharam difícil ou muito difícil a vaporização em olho fechado e 34% a instilação de colírio (p=0,9562). A dificuldade mais comum para ambos os métodos foi "acertar o olho" e ocorreu em 53% dos pacientes que tiveram dificuldades para vaporização e por 65%dos que apresentaram dificuldade para aplicação de colírio. 38% dos pacientes necessitaram de mais de uma instilação para aplicação do colírio, enquanto 30% dos pacientes precisaram de mais de uma aplicação para que a droga vaporizada tivesse contato com o olho (p=0,5224). Em 74% dos pacientes houve toque da ponta do colírio com os cílios, já com ...


Objective: Evaluate how difficult it is to apply ocular topical medications based on patient observation and answers to a questionnaire. Eye drops in open eyes were compared to vaporization in closed eyes. Methods: The study was a randomized clinical trial paired and held in the months of august and september of 2012 in the ophthalmological department of Polyclinic Ronaldo Gazolla (Arcos da Lapa Campus, Faculty of Medicine, University Estáciode Sá, RJ) in 50 patients. The Optive® ophthalmic solution was applied topically via an eyedrop bottle or a vaporizer through a randomized process. Patients were asked pre-formulated questions about the practicality of both methods and the technique of topical ocular drug delivery was observed. Results: 32% informed that it was difficult or very difficult to vaporize and 34% to use eye drops (p=0,9562). The major problem described by patients was to direct the eye drop to the eye surface. This difficulty was considered by 53% for vaporization and by 65% for topical eye drop use. 38% of the patients needed more than one eye drop application to have eye drop contact, while 30% of the patients needed more than one application of vaporization in order to get drug eye contact (p=0,5224). In 74% of patients there were an eyedropper tip contact with cilia, however there was one eye finger contact when the medicine was vaporized (p=0,5433). Conclusion: The ease perceived by patients to instil eye drops in open eyes was equivalent compared to the vaporization in closed eyes; the method of spraying was performed more appropriately due to the high frequency of eyedrop tip touches on the ocular surface. .


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Soluções Oftálmicas/administração & dosagem , Administração Oftálmica , Instilação de Medicamentos , Nebulizadores e Vaporizadores , Autoadministração , Distribuição Aleatória , Inquéritos e Questionários , Sistemas de Liberação de Medicamentos/métodos , Aerossóis
14.
Artigo em Inglês | LILACS | ID: lil-672211

RESUMO

Os excipientes são materiais amplamente utilizados para formular fármacos através de compressão direta. No entanto, as propriedades do pó e compressão desses materiais são afetadas pela presença de lubrificantes e ingredientes ativos. Este estudo utilizou uma metodologia para avaliar a eficácia destes materiais como agentes de compressão direta. O efeito de três lubrificantes (estearato de magnésio, ácido esteárico e talco) na compressibilidade e compactação dos materiais foi avaliado pelo índice de compressibilidade e sensibilidade do lubrificante, respectivamente. Da mesma forma, a capacidade da diluição foi avaliada com um fármaco pouco compressível como o acetaminofeno. Finalmente, a recuperação elástica dos comprimidos foi avaliada aos cinco dias após a produção. Todos os lubrificantes aumentaram a compressibilidade destes materiais e a sua fluidez. No entanto, os lubrificantes hidrofóbicos, tais como o estearato de magnésio tem um efeito negativo sobre a compactação, em especial em materiais plásticos com uma superfície lisa, como o amido 1500. O amido de arroz e de mandioca e ácido algínico apresentaram a maior recuperação elástica (> 5%), indicando uma elevada tendência para a laminação. Além disso, os materiais plásticos com alta deformação, tais como o sorbitol, e polivinilpirrolidona (PVP-K30), exibiram a melhor potencial de diluição (~10%), enquanto que o ácido algínico mostrou um valor muito elevado (~ 70%). Em termos de desempenho, o sorbitol, o PVP-K30, alginato de sódio, Avicel PH-101, e de amido pré-gelatinizado são os materiais mais adequados para a compressão direta de fármacos.


Excipients are widely used to formulate solid drug forms by direct compression. However, the powder-forming and tableting properties of these excipients are affected by the presence of lubricants and active ingredients. In this study, a screening methodology was employed to test the performance of an excipient for direct compression. The effects of three lubricants (magnesium stearate, stearic acid and talc) on the compressibility and compaction of these excipients were assessed by the compressibility index and lubricant sensitivity ratio, respectively. Likewise, the dilution potential in blends with a poorly compactible drug such as acetaminophen was also assessed. Finally, the elastic recovery of tablets was evaluated five days after production. All lubricants increased the compressibility of these excipients and improved their flowability. However, hydrophobic lubricants such as magnesium stearate had a marked negative effect on compactibility, especially in plastic-deforming and more regularly-shaped materials with a smooth surface such as Starch 1500. Alginic acid, rice and cassava starches had the largest elastic recovery (>5%), indicating a tendency to cap. Moreover, highly plastic deforming materials such as sorbitol and polyvinylpyrrolidone (PVP-K30) exhibited the best dilution potential (~10%), whereas alginic acid showed a very high value (~70%). In terms of performance, sorbitol, PVP-K30, Avicel PH-101, sodium alginate and pregelatinized starch were the most appropriate excipients for the direct compression of drugs.


Assuntos
Diluição , Excipientes Farmacêuticos/análise , Preparações Farmacêuticas , Ligantes
15.
An. bras. dermatol ; 86(4,supl.1): 53-56, jul,-ago. 2011. ilus
Artigo em Português | LILACS | ID: lil-604120

RESUMO

Elaioconiose é uma dermatose ocupacional do tipo acneiforme que afeta as áreas expostas de trabalhadores que lidam com óleos ou graxas. Atualmente, com o uso dos equipamentos de proteção individual, medidas de higiene pessoal e lavagem dos uniformes de trabalho, sua incidência diminuiu. Apesar de não ser uma doença rara, é pouco relatada na literatura, principalmente na nacional. Seu tratamento é lento e para a resolução das lesões, requer o afastamento do trabalhador de suas atividades laborativas.


Elaioconiosis is a work-related acneiform dermatosis which affects the exposed skin of individuals working with oils or greases. Its incidence has decreased with the introduction of personal protective equipment, personal hygiene measures and the cleaning of work clothes. Although not a rare disease, elaioconiosis is seldom reported in the literature, particularly in Brazil. Sufferers need to take time off work to proceed with the prolonged treatment to resolve the lesions caused by this condition.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Dermatite Ocupacional/etiologia , Dermatoses da Mão/induzido quimicamente , Óleos Industriais/toxicidade , Dermatite Ocupacional/patologia , Dermatoses da Mão/patologia , Licença Médica
16.
Rev. bras. oftalmol ; 70(4): 224-229, jul.-ago. 2011. ilus, tab
Artigo em Português | LILACS | ID: lil-601020

RESUMO

OBJETIVOS: Avaliar por meio de questionário, qual o grau de dificuldade para aplicação tópica de medicações oculares, com ou sem o auxílio do apoio facial. Observar qual método foi tecnicamente melhor utilizado para aplicação de drogas tópicas oculares. MÉTODOS: O estudo foi um ensaio clínico controlado e randomizado, realizado em 50 pacientes no decorrer de 2009 e 2010 na Unidade de Saúde da Família - Lapa. Foi utilizado um frasco de colírio Oftane® e o mesmo foi acoplado ao dispositivo de apoio facial. Cada participante aplicou em cada um dos olhos, a solução com ou sem o uso do dispositivo, sendo que a seleção foi feita através de um processo randomizado. Foi perguntado ao paciente questões pré-formuladas sobre a praticidade de ambos os métodos. RESULTADOS: Considerando o grau de dificuldade de administração tópica ocular: 12 por cento acharam difícil ou muito difícil a aplicação com o objeto de apoio facial e 22 por cento sem o apoio (p=0,0024). As dificuldades descritas pelos pacientes foram relatadas por 22 por cento dos pacientes para aplicação com o dispositivo de apoio facial e por 46 por cento para aplicação sem o mesmo. Já 34 por cento dos pacientes necessitaram de mais de uma instilação para aplicação do colírio sem o apoio, enquanto que 54 por cento dos pacientes precisaram de mais de uma aplicação para que a gota atingisse o olho com o auxílio do apoio facial (p= 0,04). Em 56 por cento dos pacientes houve toque da ponta do colírio com os tecidos oculares, quando o objeto de apoio facial não foi usado, porém quando ele foi utilizado, apenas 2 por cento dos pacientes observados tocaram os tecidos oculares (p=0,0001). CONCLUSÃO: É mais fácil a instilação de colírios com o auxílio do dispositivo de apoio facial. Este também dificulta o contato da ponta do frasco com os tecidos oculares, prevenindo a contaminação do frasco.


OBJECTIVE: Evaluate how difficult it is to apply ocular topical medications with and without an eye dropper facial applicator based on patient observation and answers to a questionnaire. METHODS: The study was a controlled and randomized clinical trial performed in 50 patients during the years of 2009 and 2010 in PSF - Lapa. Eye drops were applied with and without aid of an eye dropper facial applicator. Each individual tested applied randomly on one of their eyes an eye drop with or without the applicator. The patients had to answer questions about the practice concerning both forms of topical eye drug application. RESULTS: 12 percent informed that it was difficult or very difficult to instill eye drops and 22 percent to instill eye drops helped by an eye dropper facial applicator (0,0024). Problems described by patients were considered by 22 percent for eye drops with the applicator and by 46 percent for topical eye drop instillation without it. 34 percent of the patients needed more than one eye drop application to have eye drop contact , while 54 percent of the patients needed more than one application with the eye drop facial applicator in order to get drug eye contact (p= 0,04). In 56 percent of patients there were an eyedropper tip contact with ocular tissues, however there was only 2 percent of contact when the eye drop was instilled aided by the applicator (p=0,0001). CONCLUSION: It is easier to instill an eye drop with the help of an eye dropper applicator than without it. This dispositive also reduces the eyedropper tip contact with the ocular tissues.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Soluções Oftálmicas/administração & dosagem , Autoadministração , Sistemas de Liberação de Medicamentos/instrumentação , Lubrificantes Oftálmicos/administração & dosagem , Inquéritos e Questionários , Administração Tópica , Cooperação do Paciente , Embalagem de Medicamentos , Administração Oftálmica
17.
Rev. bras. oftalmol ; 68(6): 327-331, nov.-dez. 2009. tab
Artigo em Português | LILACS | ID: lil-543763

RESUMO

OBJETIVO: Avaliar por questionário qual o nível de dificuldade para aplicação tópica de medicações oculares: vaporização ou gotas através da observação do paciente e qual método foi tecnicamente melhor utilizado para aplicação de drogas tópicas oculares. MÉTODOS: A pesquisa foi realizada no decorrer de 2008 e 2009 no ambulatório de oftalmologia da Policlínica Ronaldo Gazolla. Foi utilizado um frasco de colírio e um de vaporizador com solução de carboximetilcelulose sódica a 0,5 por cento. Cada participante aplicou em um dos olhos a solução por vaporização ou instilação de gotas através de um processo randomizado. Foi perguntado ao paciente questões pré-formuladas sobre a praticidade de ambos os métodos. RESULTADOS: Considerando o grau de dificuldade de administração tópica ocular: 36 por cento acharam difícil ou muito difícil a vaporização e 14 por cento a instilação de colírio. As dificuldades descritas pelos pacientes foram relatadas por 64 por cento dos pacientes para vaporização e por 34 por cento para aplicação de colírio (p= 0,0027). Já 42 por cento dos pacientes necessitaram de mais de uma instilação para aplicação do colírio, enquanto 36 por cento dos pacientes precisaram de mais de uma aplicação para que a droga vaporizada tivesse contato com o olho (p= 0,49). Em 56 por cento dos pacientes houve toque da ponta do colírio com os cílios, já com o vaporizador não houve toque (p=0,0001). CONCLUSÃO: A vaporização foi o método mais seguro para evitar a contaminação do frasco. A maior facilidade percebida pelos pacientes ao instilar o colírio em relação a vaporização foi devido a terem apoiado a ponta do frasco nos tecidos oculares.


OBJECTIVE:Evaluate how difficult it is to apply ocular topical medications based on patient observation and answers to a questionnaire. Eye drops were compared to vaporization. METHODS: The study was performed in 2008 and 2009 in Policlinica Ronaldo Gazolla ophthalmological ambulatory. An eyedropper and a vaporizer with carboximetilcelulose 0,5 percent were used. Each individual tested applied randomly on one of their eyes an eye drop or vaporization. The patients had to answer questions about the practice concerning both forms of topical eye drug application. RESULTS: 36 percent informed that it was difficult or very difficult to vaporize and 14 percent to use eye drops. Problems described by patients were considered by 64 percent for vaporization and by 34 percent for topical eye drop use (p= 0,0027). 42 percent of the patients needed more than one eye drop application to have eye drop contact , while 36 percent of the patients needed more than one application of vaporization in order to get drug eye contact (p= 0,49). In 56 percent of patients there were an eyedropper tip contact with cilia, however there was not contact when the medicine was vaporized (p=0,0001). CONCLUSION: Vaporization was the safest method to avoid topical ocular drug contamination by manipulation; the greater facility noticed for patients when they administered eye drops was achieved using eye tissues as an eyedropper support.


Assuntos
Administração Tópica , Olho , Autoadministração , Soluções Oftálmicas/administração & dosagem , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...